Cyberdata Paging Unit Manual Configuration
Table of Contents
Scope:
The following steps will allow you to provision a Cyberdata paging unit with your service
Items Needed:
- Cyberdata Paging Unit plugged into the network
- Web browser with access to same LAN as Cyberdata
- Access to the Manager Portal (Office Manager or Above)
Obtain SIP Credentials
- Using any web browser log in to the Manager Portal
- Click on Users at the top
- Find your extension number. At the far right click on the pencil, and then Phones
- Click on Add Phone
- Leave as default and then click Add
- The page will refresh and you will now see your extension in the list. Click on the pencil again
- Note the information in the popup. You will need it for the next step
Find Cyberdata IP Address
The default address is 10.10.10.10. If the device is placed on a network with a DHCP server, it will pull the DHCP address.
- Connect the Cyberdata to a speaker
- Quickly press and release the RTFM button on the back of the device.
- The IP address will play over the speaker.
Configure Cyberdata
- Using any web browser navigate to the IP address from the above step
- Log in. The default credentials are admin / admin
- Click on SIP at the top
- Fill out the following:
- Enable SIP operation: checked
- Register with a SIP Server: checked
- Buffer SIP Calls: unchecked
- Primary SIP Server: Domain/Proxy from PBX Portal
- Primary SIP User ID: Username from PBX Portal
- Primary SIP Auth ID: Username from PBX Portal
- Primary SIP Auth Password: Password from PBX Portal
-
Re-registration Interval (in seconds): 60
- Scroll to the bottom and fill out the following:
- Outbound proxy: outbound proxy from the portal
-
Outbound Proxy Port: 5060
- Click Save. The device should show registered in the portal and on the home screen.